Description

Product Overview

Spirax Sarco SG253 is an SG iron double window sight glass with flanged pipeline connections. Installed downstream of steam traps and along liquid or gas process lines, it enables operating personnel to observe flow conditions, detect pipeline equipment blockages, and verify process media color.

Spirax Sarco SG253 flanged double window sight glass

The internal flow passage incorporates a smooth concentric reduction at the inlet connection that promotes turbulence as fluid moves through the body, increasing the visibility of clear liquids through the borosilicate glass windows. The opposing window configuration facilitates backlighting for quick visual inspection.

Key Features

  • Spheroidal graphite iron body and cover (EN-JS1025 / DIN 1693 GGG 40.3) rated for working pressures up to 25 bar g.
  • Double opposing borosilicate glass windows conforming to DIN 7080 permit clear through-lighting.
  • Concentric inlet bore reduction generates localized turbulence to aid optical detection of passing fluids.
  • Reinforced exfoliated graphite gaskets with thin stainless steel support rings provide tight joint containment.
  • Dual standard flange compatibility covering EN 1092 PN25 and BS 1560 ASME (ANSI) Class 150 across DN15 to DN50 sizes.
  • Compliant with EU Pressure Equipment Directive 2014/68/EU (Sound Engineering Practice for DN15 to DN40; Category 1 for DN50 Group 2 gases).
  • Availability of Typical Test Reports and EN 10204 3.1 inspection certification when requested at time of order.

Technical Specifications

SpecificationEN 1092 PN25 FlangedASME (ANSI) Class 150 Flanged
Body Design ConditionsPN25ASME (ANSI) 150
Maximum Allowable Pressure (PMA)25 bar g @ 100 °C (362.5 psi g @ 212 °F)17.2 bar g @ 35 °C (249.5 psi g @ 95 °F)
Maximum Allowable Temperature (TMA)280 °C @ 18 bar g (536 °F @ 261 psi g)280 °C @ 10 bar g (536 °F @ 145 psi g)
Minimum Allowable Temperature-10 °C (14 °F)-10 °C (14 °F)
Maximum Operating Pressure for Saturated Steam (PMO)21 bar g (304.5 psi g)13.8 bar g (200.1 psi g)
Maximum Operating Temperature (TMO)280 °C @ 18 bar g (536 °F @ 261 psi g)280 °C @ 10 bar g (536 °F @ 145 psi g)
Minimum Operating Temperature0 °C (32 °F)0 °C (32 °F)
Cold Hydraulic Test Pressure38 bar g (551 psi g)30 bar g (435 psi g)
Maximum Test Pressure (Steam Service, PTMX)21 bar g (304.5 psi g)13.8 bar g (200.1 psi g)

Spirax Sarco SG253 pressure and temperature operating limits chart

Applications

  • Visual discharge verification downstream of steam traps in saturated steam and condensate return lines
  • Diagnostic flow checking to detect blocked strainers, inoperative valves, or stuck mechanical pipeline ancillaries
  • Fluid color, clarity, and bubble checking across consecutive stages in chemical and utility pipelines
  • Service duties carrying Group 2 industrial fluids including steam, compressed air, and water

Materials of Construction

ItemPartMaterialStandard
1BodySG ironEN-JS1025 / DIN 1693 GGG 40.3
2CoverSG ironEN-JS1025 / DIN 1693 GGG 40.3
3WindowBorosilicate glassDIN 7080
4GasketsReinforced exfoliated graphite-
5Cover boltsSteelBS 3692 Gr. 8.8

Dimensions and Weights

Dimensions are stated in millimeters (mm) and weights in kilograms (kg):

SizePN25 Length (A)ASME 150 Length (A)Height (B)Cover Width (E)Window Flange Projection (F)Weight (kg)
DN151301265545103.2
DN201501425545104.1
DN251601527063155.0
DN321801757063155.9
DN402001999080209.1
DN5023022890802010.9

Spirax Sarco SG253 dimensions and construction schematic

Installation and Safety Guidelines

  • Stop valves must be installed on both the inlet and outlet connections. The upstream stop valve must always be closed first when isolating to prevent overpressurisation.
  • Mounting orientation is permitted in either horizontal or vertical pipework.
  • When installed on the outlet of blast discharge steam traps (such as thermodynamic traps), the sight glass must be placed at least 1 meter away from the trap to isolate the glass from severe thermal shock and hydraulic pulsations.
  • Operators must wear protective eyewear when inspecting through the sight glass. Corrosive chemicals in condensate (particularly caustic alkalis or hydrofluoric acid) can cause window erosion and thinning over time; windows showing signs of thinning must be replaced immediately.
  • Ensure sufficient clearance is provided around the unit to facilitate cover bolt removal and maintenance.

Maintenance and Spare Parts

Before servicing, isolate the sight glass from pressure, vent the body safely to atmospheric conditions, and allow internal temperature to cool to ambient.

Window and Gasket Replacement Procedure:

  1. Loosen and remove cover bolts (5) and covers (2).
  2. Extract old gaskets (4) and borosilicate windows (3).
  3. Thoroughly clean the body recess faces without scratching the seating surfaces.
  4. Fit new gaskets and windows, ensuring one gasket (4) is positioned on either side of each window (3).
  5. Reassemble covers (2) and tighten cover bolts (5) progressively to the recommended torque.
  6. Slowly open isolating valves after maintenance to restore pressure and temperature in a gradual manner, then inspect for leaks.

Spirax Sarco SG253 exploded view and spare parts identification

Recommended Tightening Torques:

ItemSizeBolt QtyWrench / Socket SizeBolt SpecificationTightening Torque
5DN15 - DN20817 A/FM10 x 3012 N m (8.6 lbf ft)
5DN25 - DN32 (Pre 08-2010)817 A/FM10 x 3528 N m (20.6 lbf ft)
5DN25 - DN32 (Post 08-2010)816 A/FM10 x 4028 N m (20.6 lbf ft)
5DN40 - DN50819 A/FM12 x 4038 N m (28.0 lbf ft)

Available Spare Parts:

  • Set of windows and gaskets (Items 3, 4): Contains replacement DIN 7080 borosilicate glass windows and graphite gaskets. For DN25 and DN32 units, an extra set of M10 x 40 (16 A/F) cover bolts is included to accommodate the thicker glass window.
  • Set of gaskets (Item 4): Contains replacement graphite gaskets with internal stainless steel support rings.
WeChat ID copied